Talonavicular joint arthrodesis with VariAx plate. Zimmer Biomet or its affiliates unless otherwise indicated, and must Arthrex Quickset -Calcium Phosphate Bone Filler Arthrex Quickset can be used to help stabilize bone fragments within highly comminuted fractures All-In-One Device Easy and fast Closed mixing system Endothermic mixing reaction Injectable Optimized Composition Good mechanical compression strength Proper viscosity and macroporosity due to polysaccharide polymer Excellent cohesiveness, which prevents Biologic Properties Biocompatible Osteoconductive Radio-opaque High Degree of Porosity Porous structure with different pore sizes Permeable to cells Fully *Prices are pre-tax. With a 1.6-mm low profile and flush-sitting Liked by Jessica Maquet, LAT, ATC In the largest series to date, Hoshino reported on 448 patella fractures treated surgically. satisfaction about your patients surgical preparation and recovery. It covers the incision, the desired outcome, the osteotomy and then two different methods of fixation. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. Depending on the force applied, it may create a hairline crack, break into two pieces or it may break into many small pieces. and treatment algorithm for patella fractures, including recent advancements in surgical technique to optimize outcomes and minimize complications. System Surgical Technique, These two new plate designs expand upon Zimmer 2 There is no consensus, however, regarding many other facets of management of the syndesmosis, including . Your knee may also become stiff after healing has occurred. Patella SuturePlate System Offers a unique and ultimate rigid method for the accurate reduction of patella fractures. locking The patella is covered with cartilage, which provides a cushion for your knee joint. Distal femur fractures are traumatic injuries involving the region extending from the distal metaphyseal-diaphyseal junction to the articular surface of the femoral condyles. The patella is then inverted to permit direct visualization of fracture fragments and the articular surface 33 ( Fig. Diagnosis is made radiographically with CT studies often required to assess for intra-articular extension. They might have you try to extend your leg. Place pedicle screws in the vertebrae caudal and cephalad to the involved vertebra in preparation for posterior instrumentation (Fig. With anatomically contoured plates designed or validated using our proprietary SOMA technology, streamlined instrumentation, and trained representatives, our plating portfolio is designed with you in mind. trajectory of the screw hole may not be ideal. addition to these locking screw designs, a cobalt chrome3.5 mm The patented polyaxial locking technology and low profile design were created using our SOMA database. To prevent disruption of the medially based vascular supply to the patella,34 a lateral parapatellar arthrotomy is then performed, fracture hematoma is evacuated, and the knee joint is irrigated. sustentaculumtalitomaximize screw purchase and trajectory to limit Minimally-Invasive and Mesh Calcaneus Plating System Suture holes in the plate can be optionally used for soft-tissue reattachment or ligament bracing. PEEKPower Humeral Fracture Plate Anatomically designed radiolucent multidirectional locking plate made of carbon fiber reinforced PEEK in combination with titanium screws. The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. It covers the incision, the desired outcome, the osteotomy and fixation. The mesh plates combine an MIS plate design with Unique to this set is an adjustable parallel offset guide, a C-ring drill guide with an incorporated measurement device, and a cerclage wire passer to effectively pass wire through the quad and patellar tendons. Plating options that includes low-profile fracture utility plates, 3 different 5th metatarsal fracture plates and a pinch plate designed to facilitate distal metatarsal osteotomies, Versatile, low-profile plate designs are Type II anodized, pairing increased strength* with minimal construct prominence, Every 3Di screw hole accepts either a 2.0mm or 2.4mm non-locking or polyaxial locking screw, addressing variations in fracture patterns and patient anatomies. Cleveland Clinic is a non-profit academic medical center. The Patella Fracture System includes everything needed to repair transverse patella fractures. This construct has been shown to be stronger than the traditional K-wire with cerclage wire constructs.1. This plate functions similarly to a one-third tubular plate but is more contoured and includes a distal cluster of 2.7 mm hexalobe screws to capture fragments in cases with distal comminution. Hand & Wrist PEEKPower Distal Radius Plate A multidirectional, volar plating system made of carbon fiber (CF) reinforced PEEK in combination with titanium screws. The Mesh plates The primary packaging has been selected to not include latex in any form. This video depicts a correction of a hallux valgus deformity using a lapidus procedure, a fusion of the first metatarsal with the medial cuneiform. Patella fracture is commonly caused by either direct trauma (e.g. Coming to a Cleveland Clinic location?Hillcrest Cancer Center check-in changesCole Eye entrance closingVisitation, mask requirements and COVID-19 information, Notice of Intelligent Business Solutions data eventLearn more. The set is designed to fix transverse patella fractures. Then, with the knee in 60-90 degrees of flexion and the patella maintained in the center of the patellar groove, the ends of the FiberTap are secured to the femoral side with one 4.75 mm knotless anchor nail (Figure 1e) [2,36,127,128,129,130] The double tunnel reconstruction used on the patellar side reduces the risk of patellar fracture due . All other trademarks are trademarks of their respective owners or holders. Fit for patients Fit for procedures Fit for you Fit for the future Contact Related categories Orthopaedics accurate screw insertion, radiolucent for enhanced x-ray But opting out of some of these cookies may have an effect on your browsing experience. This video demonstrates a calcaneal cuboid fusion. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. Stainless Steel, Type I Anodized titanium, and machined angulation) off center. Screw is also available to compress the plate to the bone. It covers the incision, the desired outcome, the osteotomy and fixation. Follow the guidance of your healthcare provider and avoid too much activity too soon. Mller EC, Frosch KH. Some patella fractures are simple, but this small bone is also capable of breaking into many pieces. Your healthcare provider will guide you through the process to ensure that you restore as much mobility as possible to your knee. 9500 Euclid Avenue, Cleveland, Ohio 44195 |, Important Updates + Notice of Vendor Data Event, (https://orthoinfo.aaos.org/en/diseases--conditions/patellar-kneecap-fractures/), Visitation, mask requirements and COVID-19 information, Non-steroidal anti-inflammatory drugs (NSAIDs). A growth plate fracture affects the layer of growing tissue near the ends of a child's bones. titanium.1Anatomic screw trajectories are designed to options for calcaneus fracture management.. Apple Watch and iPhone are trademarks of Apple, Inc., registered in This site is for visitors from the United States. surgeon to direct the screw up to 15 degrees (30 degreecone of Resource Type: In addition, FiberTape. This video demonstrates a lateral column lengthening. Patella fractures represent approximately 1% of all fractures and present in a variety of patterns, which can make osteosynthesis challenging. Medial column arthrodesis with VariAx plate. Certain products may not be approved for sale in all countries. Case series of patellar plating have been reported, 7 and biomechanical studies have shown equivalent or superior results with plate fixation as compared to tension banding. Palpable patellar defect (a change in your kneecap that you can feel through your skin). Wright PB, Kosmopoulos V, Cot RE, Tayag TJ, Nana AD. This site is intended for healthcare professionals. Patented SmartLock polyaxial locking technology, Locking screws can be angled 15 for a total range of 30. This video demonstrates a talonavicular fusion. This set includes 4.0 mm blunt-tip cannulated lag screws, which feature smooth tips to help avoid cutting suture, and a specially designed 5-in needle for easily passing suture through the screws to create tension-band fixation. the plate will alter targeting guide alignment. the US and other countries. designed to be bent or altered by the surgeon. The adaptability design allows for modularity and variable angles, you can base screw positoning on your patient at hand, not a plate's pre-existing design. address a variety of calcaneus fractures, while meeting the stress Locking plate system for reconstruction or arthrodesis of small bones, including the fore, mid- and hind foot and ankle. Principles. Meanwhile, its very important to be patient and committed to the healing process. To address various types of fractures, the Patella SuturePlate II system offers three types of plates in different sizes. experience.Mymobilitydelivers continuous data and The fracture pattern can be transverse, vertical or stellate [ 3 ]. options for calcaneus fracture management.. Necessary cookies are absolutely essential for the website to function properly. Secure and stabilize ankle fractures with Arthrex's ankle fracture and distal tibia plating system. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. Non-Locking Screws. Compression and locking in one step. benefitof increased fatigue strength compared to 316L Electropolished Lateral column lengthening with VariAx plate. The mesh plates, which are offered in short and long lengths, can be cut and contoured to the desired size and shape based on fracture patterns. The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. maximize screw position and limit intra-articular and neurovascular The A.L.P.S. This may lead to arthritis of the knee joint. warnings, precautions, potential adverse effects and patient PEEKPower Tibial Head Fracture Plates Lateral and Posteromedial A combination of titanium locking screws and a radiolucent carbon reinforced PEEK plate. Broken pieces may move out of line or break through the skin. On the other hand, Lee et al. All fibula plates are engineered to work seamlessly with our proven Syndesmosis TightRope implants. All plates are made of titanium and have a low-profile thickness of 1.6 mm with screws sitting flush on the plate. The aim of the PSCG is to dene the PSCG is anatomical. More rarely, it can also be caused by a sudden muscle contraction in your knee. The anatomically contoured plate is designed to replicate the patient's specific scapular anatomy, thereby resulting in a more secure reconstruction of severely displaced fractures. In extended 2-Hole, large extended 2-Hole, and large extended 3-Hole The cartilage can be injured with this type of fracture, which can lead to post-traumatic arthritis. Recovery can be long, and side effects are common. Dr. Adam Schiff demonstrates a Metatarsal Fracture procedure using VariAx fracture plates. The patella SuturePlate (Fa. the calcaneus will allow good plate/bone apposition. Keywords: Patella, Fractures, Mesh plates INTRODUCTION Fractures of the patella account for about 1% of all skeletal injuries. . Adequate reduction of Screw options and instruments to address a 1 It is generally accepted that instability of the syndesmosis after stable fracture fixation requires reduction and fixation in order to optimise the outcome. Modification of injury to tendinous and neurovascular structures, while limiting Your healthcare provider may recommend trying to avoid stairs, squatting and bending, when possible, to limit stress on your knee and prevent future complications. Screw System - Quick and Easy Screw Fixation with the Low Profile Snap-off Screw - LS0451, Trim-It Drill Pin - The need to remove hardware is disappearing - LS0441, Arthrex Knotless TightRope - LS2-0426-EN, Arthrex Power System 600 - Quality you can trust, Performance you can count on - LS2-0600-EN, Trim-It Drill Pin All-Inside Technique - LS1-0443-EN, ArthroBrostrom The Only Arthroscopic Ankle Ligament Repair Kit - LS1-0490-EN, Freedom in Anatomic Femoral Socket Placement - LS0187, Quantified Precision with the T3 AMZ System - Tibial Tuberosity Transfer with Anteromedialization - LS0145, Percutaneous Glenohumeral Repair with SutureTak Implants - LS0508, Collagen Coated FiberWire Suture - LS1-0235-EN, InternalBrace? Tabs that can be contoured to The low-profile plates are available in a wide range that intra-articular screw placement. The subtalar Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw 1, 2 In total, 70% to 90% of patella fractures are transverse, with most. Current accepted surgical options. This allows the The Patella Fracture Set was specifically designed to address common obstacles (eg, amount of comminution, degree of osteoporosis, and natural forces across the patella) and to facilitate fixation of challenging injuries. The mechanism of injury . 2.7 mm, 3.5 mm and4.0 mm locking screws that can be inserted into where additional screw options may be required. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. Proximal Humerus Fracture Repair with Arthrex SuturePlate Arthrex 76.8K subscribers Subscribe 353 Share 69K views 6 years ago Show more Show more Comments are turned off. Abstract. Dr. Adam Schiff demonstrates a Fifth Metatarsal procedure using VariAx fracture plates. the calcaneus anatomy as needed. In addition, FiberTape suture has been attached to 5 in needles designed to pass through the screws, subsequently allowing for its use as a tension band. Plating options that includes low-profile fracture utility plates, 3 different 5th metatarsal fracture plates and a pinch plate designed to facilitate distal metatarsal osteotomies Versatile, low-profile plate designs are Type II anodized, pairing increased strength* with minimal construct prominence Tight screw density on the distal and proximal ends with larger bridges near the center of the plate allows surgeons to fit more screws in the same footprint than competitive plates. 3). Minimally-Invasive and Mesh Calcaneus Plating System features two distinct and anatomically contoured plate designs that address a variety of calcaneus fractures, while meeting the stress requirements present in the trabecular anatomy of the calcaneus. not be redistributed, duplicated or disclosed, in whole or in part, 3 drill holes from inferior pole to superior pole of patella with 2.0mm drill. visualization, and allow for percutaneous screw placement., The anatomic shape of the plate allows screw trajectories to Radiological studies revealed right distal radial fracture in two locations. Biometsexistingnon-locking perimeter plate and the A.L.P.S. Innovative instruments are included along with sternal wire drivers, Weber clamps, drill guides, and Stout wire cutters, giving surgeons all necessary instruments needed in one convenient set. Ce site est destin aux professionnels de sant.Etes-vous un professionnel de sant? The A.L.P.S. All content herein is protected by copyright, trademarks and other Arthrex, Inc. Data on file (Patella Fracture Study [Study #318]). The Right Material For Each Indication Properties of Titanium Alloy Implants Corrosion resistant Low modulus of elasticity (prevents stress shielding) Enhanced MRI & CT resolution (fewer artefacts) Non-allergenic Permanent implantation option Properties of Stainless Steel Implants Ductility (bendable) High strength (significantly stiffer than titanium alloy) Reduced oss. This video demonstrates a medial column fusion. , This material is intended for health care professionals. The adaptability design allows for modularity and variable angles, you can base screw positoning on your patient at hand, not a plate's pre-existing design. Arthrex, Inc. products are designed without any latex components or packaging. It can take a long time to strengthen your thigh muscles after a patella fracture. calcaneus plate portfolio therefore providing comprehensive plating FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures. Distal Femur Fractures. Calcaneo cuboid arthrodesis with VariAx plate. These anatomically contoured plates are not Think Arthrex, Radiolucent Excellent biocompatibility Modulus of elasticity is close to that of cortical bone Artifact-free radiographic imaging Inert properties reduce tissue adhesion Improved long term stability Plates Available in CF PEEK PEEKPower humeral fracture plate PEEKPower tibial fracture plate PEEKPower distal radius plate CF PEEK Implants Are Composed of the Following Materials PEEK (a) Endless longitudinal carbon fibers (b) Tantal fibers for radiological control (c) (b), Shoulder Clavicle Plate System Designed to treat central third and distal clavicle fractures. Retinacular Closure. Plates -Ti-6Al-4V ELI,Type 2 Anodized Titanium Alloy. If you think you can, but it is still painful, its probably best not to try until you have been diagnosed. Practical guidelines for the treatment of patellar fractures in adults. Calcaneal Fracture System Designed to be the most comprehensive solution for calcaneal fracture fixation perimeter and percutaneous plates. Arthrex - Patella Fracture System Patella Fracture System The Patella Fracture System includes everything needed to repair transverse patella fractures. Overview This technique is used to stabilize an ankle after injury. Make sure to follow through with physical therapy after your fracture has healed, in order to restore your muscle strength and range-of-motion. 2). The healing process for a patella fracture can vary, depending on the severity of your break and whether you had surgery or not. Technique Animation, The MIS plates are specifically designed for a small incision using a A vision requires leadership to become reality. Low Profile VA Locking Screw, 3.0 x 10 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 12 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 14 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 16 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 18 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 20 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 22 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 24 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 26 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 28 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 30 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 32 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 34 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 36 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 38 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 40 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 40 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 42 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 44 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 46 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 48 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 50 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 52 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 54 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 56 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 58 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 60 mm, Titanium, QuickFix Screw, Titanium, Cannulated, Short Thread, Cancellous 4.0 x 28 mm, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 30 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 32 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 34 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 36 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 38 mm, Titanium, Handle, Quick Coupling Ratcheting, Cannulated, Bone Reduction Forceps, Curved, Pointed, qty 2, Drive Shaft, Cannulated, QC, T15 Hexalobe, Screw Holding Sleeve for 2.7, 3.5 and 4 mm Screws, Surgical Technique Guides | English | 03/03/2023 | LT1-000206-en-US B, Surgical Technique Animations | 02:13 | English | 01/13/2023 | AN1-000279-en-US B, Surgical Technique Videos | 04:22 | English | 02/04/2022 | VID1-003070-en-US A, Brochures | English | 01/28/2021 | LB1-000259-en-US A, 04:22 | English | 02/04/2022 | VID1-003070-en-US A, 02:13 | English | 01/13/2023 | AN1-000279-en-US B, English | 03/03/2023 | LT1-000206-en-US B, English | 01/28/2021 | LB1-000259-en-US A. Utilizes multiple A.L.P.S. K-wire fixation with metal tension band were used for fixation in 315 (70%) patients and cannulated screws were used with tension band for fixation in 133 (30%). Arthrex 2 years 10 months Shoulder Consultant Arthrex Jul 2018 - Feb 2020 1 year 8 months. place knee in extension on triangle and tie 2 pairs of knots over patella. With a multipartite patella, the volume of the true patella plus that of the smaller ossification centers is greater than that expected of a normal patella. They may also be able to feel the edges of the fractured bone pieces through your skin. A short arm cast is applied. At first, you wont be allowed to flex your knee, but flexion will be allowed slowly, over time. 3.5 mm Multi-Directional Locking Screws or 3.5 mm Low Profile Licensed from Prof. D. Wolter, Hamburg, GermanyStryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Anchorage, Stryker, VariAx. correspond to the complicated anatomy of the calcaneus. could be slightly varied (outside of the targeting guide) with either flexibility with perimeter F.A.S.T. Incision is made, distal radius is identified, manipulated into place, and two pins across both fragments to maintain alignment. 25608-RT (Open fracture repair was performed of the distal radius. If you cant, that will likely necessitate surgical intervention. This capacity is influenced by bone mineral density, but also by bone geometry, microstructure and quality. When the time is right, be diligent with your physical therapy exercises. Straight Plate Broad, Titanium, 1.6 mm, 5 Hole, Straight Plate Broad, Titanium, 1.6 mm, 6 Hole, Straight Plate Broad, Titanium, 1.6 mm, 7 Hole, Straight Plate Broad, Titanium, 1.6 mm, 8 Hole, Straight Plate Broad, Titanium, 1.6 mm, 9 Hole, Straight Plate Broad, Titanium, 1.6 mm, 10 Hole, T-Plate, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 1.6 X 6 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 7 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 8 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 9 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 10 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 11 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 12 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 13 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 14 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 16 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 18 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 20 mm, Low-Profile VAL Screw, Titanium, 1.6 X 6 mm, Low-Profile VAL Screw, Titanium, 1.6 X 7 mm, Low-Profile VAL Screw, Titanium, 1.6 X 8 mm, Low-Profile VAL Screw, Titanium, 1.6 X 9 mm, Low-Profile VAL Screw, Titanium, 1.6 X 10 mm, Low-Profile VAL Screw, Titanium, 1.6 X 11 mm, Low-Profile VAL Screw, Titanium, 1.6 X 12 mm, Low-Profile VAL Screw, Titanium, 1.6 X 13 mm, Low-Profile VAL Screw, Titanium, 1.6 X 14 mm, Low-Profile VAL Screw, Titanium, 1.6 X 16 mm, Low-Profile VAL Screw, Titanium, 1.6 X 18 mm, Low-Profile VAL Screw, Titanium, 1.6 X 20 mm, Straight Plate, Titanium, 2.0 mm, 10 Hole, Straight Plate, Titanium, 2.0 mm, 11 Hole, Straight Plate, Titanium, 2.0 mm, 12 Hole, Straight Plate, Titanium, 2.0 mm, 13 Hole, Straight Plate, Titanium, 2.0 mm, 14 Hole, Straight Plate, Titanium, 2.0 mm, 15 Hole, T-Plate, Titanium, 2.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.0 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.0 X 6 mm, Low-Profile VAL Screw, Titanium, 2.0 X 7 mm, Low-Profile VAL Screw, Titanium, 2.0 X 8 mm, Low-Profile VAL Screw, Titanium, 2.0 X 9 mm, Low-Profile VAL Screw, Titanium, 2.0 X 10 mm, Low-Profile VAL Screw, Titanium, 2.0 X 11 mm, Low-Profile VAL Screw, Titanium, 2.0 X 12 mm, Low-Profile VAL Screw, Titanium, 2.0 X 13 mm, Low-Profile VAL Screw, Titanium, 2.0 X 14 mm, Low-Profile VAL Screw, Titanium, 2.0 X 16 mm, Low-Profile VAL Screw, Titanium, 2.0 X 18 mm, Low-Profile VAL Screw, Titanium, 2.0 X 20 mm, Low-Profile VAL Screw, Titanium, 2.0 X 22 mm, Low-Profile VAL Screw, Titanium, 2.0 X 24 mm, Low-Profile VAL Screw, Titanium, 2.0 X 26 mm, Low-Profile VAL Screw, Titanium, 2.0 X 28 mm, Low-Profile VAL Screw, Titanium, 2.0 X 30 mm, Straight Plate, Titanium, 2.4 mm, 10 Hole, Straight Plate, Titanium, 2.4 mm, 11 Hole, Straight Plate, Titanium, 2.4 mm, 12 Hole, Straight Plate, Titanium, 2.4 mm, 13 Hole, Straight Plate, Titanium, 2.4 mm, 14 Hole, Straight Plate, Titanium, 2.4 mm, 15 Hole, T-Plate, Titanium, 2.4 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.4 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.4 X 8 mm, Low-Profile VAL Screw, Titanium, 2.4 X 9 mm, Low-Profile VAL Screw, Titanium, 2.4 x10 mm, Low-Profile VAL Screw, Titanium, 2.4 X 11 mm, Low-Profile VAL Screw, Titanium, 2.4 X 12 mm, Low-Profile VAL Screw, Titanium, 2.4 X 13 mm, Low-Profile VAL Screw, Titanium, 2.4 X 14 mm, Low-Profile VAL Screw, Titanium, 2.4 X 16 mm,Low-Profile VAL Screw, Titanium, 2.4 X 16 mm, Low-Profile VAL Screw, Titanium, 2.4 X 18 mm, Low-Profile VAL Screw, Titanium, 2.4 X 20 mm, Low-Profile VAL Screw, Titanium, 2.4 X 22 mm, Low-Profile VAL Screw, Titanium, 2.4 X 24 mm, Low-Profile VAL Screw, Titanium, 2.4 X 26 mm, Low-Profile VAL Screw, Titanium, 2.4 X 28 mm, Low-Profile VAL Screw, Titanium, 2.4 X 30 mm, Straight Plate, Titanium, 3.0 mm, 10 Hole, Straight Plate, Titanium, 3.0 mm, 11 Hole, Straight Plate, Titanium, 3.0 mm, 12 Hole, Straight Plate, Titanium, 3.0 mm, 13 Hole, Straight Plate, Titanium, 3.0 mm, 14 Hole, Straight Plate, Titanium, 3.0 mm, 15 Hole, T-Plate, Titanium, 3.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 3.0 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 3.0 X 8 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 10 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 12 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 14 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 16 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 18 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 20 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 22 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 24 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 26 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 28 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 30 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 32 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 34 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 36 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 38 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, Titanium, 3.0 X 8 mm, Low-Profile Locking Screw, Titanium, 3.0 X 10 mm, Low-Profile Locking Screw, Titanium, 3.0 X 12 mm, Low-Profile Locking Screw, Titanium, 3.0 X 14 mm, Low-Profile Locking Screw, Titanium, 3.0 X 16 mm, Low-Profile Locking Screw, Titanium, 3.0 X 18 mm, Low-Profile Locking Screw, Titanium, 3.0 X 20 mm, Low-Profile Locking Screw, Titanium, 3.0 X 22 mm, Low-Profile Locking Screw, Titanium, 3.0 X 24 mm, Low-Profile Locking Screw, Titanium, 3.0 X 26 mm, Low-Profile Locking Screw, Titanium, 3.0 X 28 mm, Low-Profile Locking Screw, Titanium, 3.0 X 30 mm, Low-Profile Locking Screw, Titanium, 3.0 X 32 mm, Low-Profile Locking Screw, Titanium, 3.0 X 34 mm, Low-Profile Locking Screw, Titanium, 3.0 X 36 mm, Low-Profile Locking Screw, Titanium, 3.0 X 38 mm, Low-Profile Locking Screw, Titanium, 3.0 X 40 mm, Low-Profile VAL Screw, Titanium, 3.0 X 8 mm, Low-Profile VAL Screw, Titanium, 3.0 X 10 mm, Low-Profile VAL Screw, Titanium, 3.0 X 12 mm, Low-Profile VAL Screw, Titanium, 3.0 X 14 mm, Low-Profile VAL Screw, Titanium, 3.0 X 16 mm, Low-Profile VAL Screw, Titanium, 3.0 X 18 mm,Low-Profile VAL Screw, Titanium, 3.0 X 18 mm, Low-Profile VAL Screw, Titanium, 3.0 X 20 mm, Low-Profile VAL Screw, Titanium, 3.0 X 22 mm, Low-Profile VAL Screw, Titanium, 3.0 X 24 mm, Low-Profile VAL Screw, Titanium, 3.0 X 26 mm, Low-Profile VAL Screw, Titanium, 3.0 X 28 mm, Low-Profile VAL Screw, Titanium, 3.0 X 30 mm,Low-Profile VAL Screw, Titanium, 3.0 X 30 mm, Low-Profile VAL Screw, Titanium, 3.0 X 32 mm, Low-Profile VAL Screw, Titanium, 3.0 X 34 mm, Low-Profile VAL Screw, Titanium, 3.0 X 36 mm, Low-Profile VAL Screw, Titanium, 3.0 X 38 mm, Low-Profile VAL Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 18 mm, Low-Profile Locking Screw, SS, 4.0 X 20 mm, Low-Profile Locking Screw, SS, 4.0 X 22 mm, Low-Profile Locking Screw, SS, 4.0 X 24 mm, Low-Profile Locking Screw, SS, 4.0 X 26 mm, Low-Profile Locking Screw, SS, 4.0 X 28 mm, Low-Profile Locking Screw, SS, 4.0 X 30 mm, Low-Profile Locking Screw, SS, 4.0 X 32 mm, Low-Profile Locking Screw, SS, 4.0 X 34 mm, Low-Profile Locking Screw, SS, 4.0 X 36 mm, Low-Profile Locking Screw, SS, 4.0 X 38 mm, Low-Profile Locking Screw, SS, 4.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 42 mm, Low-Profile Locking Screw, SS, 4.0 X 44 mm, Low-Profile Locking Screw, SS, 4.0 X 46 mm, Low-Profile Locking Screw, SS, 4.0 X 48 mm, Low-Profile Locking Screw, SS, 4.0 X 50 mm, Low-Profile Locking Screw, SS, 4.0 X 52 mm, Low-Profile Locking Screw, SS, 4.0 X 54 mm, Low-Profile Locking Screw, SS, 4.0 X 56 mm, Low-Profile Locking Screw, SS, 4.0 X 58 mm, Low-Profile Locking Screw, SS 4.0 X 60 mm, Low-Profile Locking Screw, SS 4.0 X 65 mm, Guidewire with Trocar Tip, 1.1 mm X 150 mm, Depth Device, 2.7/ 3.5/ 4.0 mm, Low Profile, Vet, Screw Holding Forceps, Self-Retaining, Vet, General OrthoLine Sterilization Case Insert, 1.6 mm and Broad 1.6 mm OrthoLine Plates and Screws, 3.5 mm and Broad 3.5 mm/4.0 mm OrthoLine Plates and Screws, OrthoLine Disposables and Limited Reusables, OrthoLine Distal Humeral Fracture System: Canine Elbow Procedure Demonstration, OrthoLine Distal Humeral Fracture System: Sawbone Application on a Canine Elbow Procedure Demonstration, OrthoLine Fracture Management System: Sawbone Application on a Canine Tibia, OrthoLine Distal Humeral Fracture System, OrthoLine Small Animal Fracture Straight Plate, OrthoLine Fracture Management System: Design Features, OrthoLine Distal Humeral Fracture Management System Weight Reference Chart, OrthoLine Fracture Management System: Weight Reference Chart, Inventory Control Form: 3.5 mm Fracture Plates and Screws, Inventory Control Form: 3.0 mm Fracture Plates and Screws, Inventory Control Form: 1.6 mm Fracture Plates and Screws, OrthoLine Universal Plating System: Clinical Case Series II, OrthoLine Fracture Management System: Clinical Case Series, OrthoLine Fracture Management System: Biomechanics, Standing Room Only: Veterinary WebInHourOrthoLine System Overview, Cortical/locking/variable-angle locking screws, Indicated for sizes from small cats to large dogs, Presenter: Sean M. Murphy, DVM, DACVS, Presenter: Mark Rochat, DVM, MS, DACVS, Presenter: Sarah Malek, DVM, PhD, DACVS-SA, Presenter: Susan Schaefer, DVM, MS, DACVS.