Now go to the breaker and turn the pump breaker off and then on again to reset the pump. codes will appear from time to time. You should also clean the heat exchanger and make sure the heater is receiving proper gas pressure. The buttons on your heaters front panel buttons will be disabled during this malfunction. All rights reserved. .
how to fix pool pump error 0002 in easy way DIY - YouTube Here is what is going on. When you wire up this pump you basically have your two hot wires coming from the breaker, and you have a ground that screws to the case of the drive. All Right Reserved by HeaterFixLab. When your heater is turned on, youll see this code on the display. insert it into the back of the pump. When your pressure switch is stuck open, you will find the Pentair pool heater error code PS on your heater display. In ERR PS, the PS stands for the pressure switch. Energy & Cost Savings Slow and steady wins the race. I also use the screwdriver to scrape away any debris that may be jammed in there. Pentair Minimax NT STD ERR message Postby Guru Thu 18 Feb, 2010 14:40 9 times out of 10 the "ERR" code is caused by a bad thermistor (temp sensor). At this point, reconnect power to the pump. The ERR IGN code indicates ignition failure. we cater to all your pool and spa needs with the utmost customer assistance. I figure after looking at this dissassembled you could tell if it was impeded by some cruft in the impeller by trying to turn it manually. service professional to trouble shoot the pump. cleared. With extensive experience in pool repair and manufacturing, They mean the same. It simply means that your heaters system is being examined for possible problems.
001a Error code on Pentair Superflo VS pump. : r/pools Pentair Variable Speed Pump IntelliFlo - Manual (Page 55) It will then begin to go into the The pump ran fine yesterday. Effect 20 RPM increments by pressing and holding the down/up button to steadily decrease or increase the pump speed. In this section, we will look at what each error code means and what are the simple solutions for these errors. What exactly should I be looking for? These error code explanations will give you some guidance for resolving the most common Pentair pool heater problems: NOTE: Any troubleshooting that involves electrical work, or opening the heat pump, should be done by a professional, What it means: temperature sensordetecting water above 107 degrees, What it means: temperature sensordetecting water below 40 degrees, What it means:the units low-pressure switch senses that water flow is open or low, What it means: remote inputs of Pool AND Spa are being triggered, What it means: water thermistor circuit is shorted, What it means: water thermistor circuit isopen/receiving constant power, What it means: defrostthermistor circuit isshorted, What it means: defrostthermistoris open; power is being interrupted, What it means:the 24 VAC supply voltage to the heat pump circuit board is low. through and into the pump impeller.
The method I always use is You should be able to press the start/stop button to start up the pump. The FLO code indicates that the water flow to your heat pump has been halted by the filter pump.
Spa Error Codes - The Big List - Leslie's Using its control panel, you can easily set and reset the 4 selectable preset speeds or set the pump speed to run at a certain speed. See "HP Indicator" LPIndicator ISSUE The refrigerant system's low-pressure switch is showing as open. This is especially useful in the afternoon when your houses cooling needs are highest and its cooling efficiency is lowest. Once the impeller spins freely the blockage has been It was scheduled to come on at 7am this morning and now its throwing the 001a error code. It Hi, I have an error code on my Pentair variable speed pump.
pentair pump is giving 0018 error code. do I need a new one? I am new to the Forum but have loved the advice and guidance I have received through here for the last two years. Pentair vs superflow model350879.A error code A1. You can easily assign up to four new speeds. Create an account to follow your favorite communities and start taking part in conversations. I got that a few times the other day while backwashing but the pump Would kick on a second or two later. It happens when the water temperature is above 135F while passing through the heat exchanger. Error Code E05: Stack Flue Sensor Is Open 2. It does this at all speeds not just one on setting. I checked voltage at the pump and I am getting 230V consistently. TradeGrade products must be purchased from a retail store (brick & mortar), pool builder or pool service company to receive a one-year, two-year or three-year warranty. internal slip and 2 in. is connected at the skimmer you may want to try the after-market Hole in One Basket Improper voltage or supply voltage. You can press the start button to assign the selected speed if necessary. Other reasons why the heater is not turning on include: Faulty igniter The defective ignition control module Bad control fuse : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order.
Pentair IntelliFlo 2 VST error codes | Trouble Free Pool It will then begin to go into the priming mode and then start up. Pentair heat pump error code LOW WATER FLOW LOW WATER FLOW What it means: the unit's low-pressure switch senses that water flow is open or low How to fix it: Check that pool pump is sending water to heater Ensure that pool pump is receiving enough water Check that your pool system's multiport valves are on the correct settings Press J to jump to the feed. The second method is to use a Allen Wrench and Edward in TX 22.4K subscribers Subscribe 35K views 2 years ago #capacitor #poolpump My Pentair pool. Check the fuel supply, the heat regulator, and any orifice blockages again. That is the overcurrent fault code. not need to do any other troubleshooting unless the Err code does not clear after But like anything electronic running from software, error getting clogged and the pump is unable to prime. The pump ran fine yesterday. If the issue code remains after taking all of these steps, the stack flow sensor may need to be replaced. Clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. Let me know what you find. The AFS being open will cause this error message to pop on your screen. ERR SFS Error Code 7. Disconnect the main power by turning off the breaker long enough for the keypad LEDs to turn off.
Pentair Superflo VS Pool Pump Error Code 0008 - McLarenblog.com So, if the pump is on, hit the start/stop button to Possible causes could be loose or damaged wiring, poor wiring connections, wrong wire type, wrong wire gauge, or issues with the relay or breaker associated with the pump. Power off the unit and restart.
Pentair VS Pump - Error Code 0021 | Trouble Free Pool Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. Try cleaning it up if the water flow is less than ideal. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. Press the down or up button to decrease or increase the pump speed. Decoding the errors on your pump 21 - Communication link between HMI and motor control has been lost The screen will display an error code as Err and then display a number. An ignition failure can be caused by a variety of heater components. WARNING: Any troubleshooting that involves electrical work is dangerous, and should be performed by a professional pool heater repair tech. Press your desired speed button (from 1 to 4) for about 3 seconds to choose the preset pump speed to reset the speed. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. Thus, the pump gave me an error code of 0008. If you have a suction side cleaner Especially, in order for a heating system to be ready for winter use, it must be serviced in the fall. We are a registered 501(c)3 non-profit that is funded by user donations. Followed instructions on page 14 of manual. Make sure to see if there is any dirt blocking the air vents or exhaust and ensure all of these items are working. If your igniter doesnt spark, it is faulty and needs replacement. The HLS may need replacement. This bond opens due to excessive heat. (The fan and impeller are on the same axle.) It is being practiced by thousands of pool owners just like you. What could be the issue here? Press question mark to learn the rest of the keyboard shortcuts. See page 14 Pump Disassembly for instructions for disassembling the pump. At this point you may want to call out a pool basket for debris and empty it when it becomes full. Thanks --Jason 02 -Absolute Phase current limit exceeded*, 08 -Absolute Diode Bridge temperature limit exceeded*, 04 -Absolute Power Module temperature limit exceeded*, 06 -Absolute Power Factor Correction (PFC) temperature limit exceeded*. Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable. When I give it power I immediately get the following error: F90052 ALARM!
I have a Pentair Superflo with error code 0002, following - JustAnswer I also use the screwdriver to scrape away any debris that may be Commercial Pool Pump Savings Calculator; Pool TDH Calculator; Encompass Overview; Pro Mobile Apps; Membrane Filtration Tools. E05 Error Code 9.
It will then begin to go into the priming mode and then start up. I apologize to anyone who found this seemingly useless video with no description. RESOLUTION pump or a poor connection. Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. jammed in there. I have not had the error since and the drive has been working great. whats up, Please note, comments must be approved before they are published. These codes are a great way to do a simple diagnostic to see what issues your pump is having. The Err 0002 will prevent the pump from running until you clear the blockage.So, if the pump is on, hit the start/stop button to turn it off. The method I always use is to remove the pump lid and pump basket, then I spin the impeller with a screwdriver.
How To Deal With Pentair Heater Error Code R14 [Solved] Quieter These pumps barely make a whisper. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. Is that an overcurrent fault code? Remove any obstructions. Your heaters ignition control module is the most likely culprit that will need to be replaced. Do you need a high pressure pump for spa jets and water features? Any suggestions? Family-owned and operated, our company has dedicated over 25 years of exceptional service. This means the motor was getting too hot. Worst company I have ever dealt with by the way.Hope this helps someone. Here's how, Shut off the whole system Regular Unscented Bleach I started doing pool service when I was 16 years old back in 1988. If the blockage was removed the screen E01/E126 Error Code 8. Power Out/OFF Does anyone knows what this means?
Pentair Heat Pump Error Codes | Pentair Pool Heater Troubleshooting Pentair Heat Exchanger Troubleshooting: The biggest fear about the heat exchanger is that corrosion can occur to the relatively soft copper finned tubes, causing them to develop pinhole leaks. I have an error code on my Pentair variable speed pump. I tried hard resetting and turning off power for multiple minutes. It may not display this or other websites correctly. So, if you have an older pool Note: The IntelliFlo's internal anti-freeze protection is disabled when connected to an IntelliTouch system. As previously said, the Pentair heater error code R14 code isnt a cause for concern. It means that the SFS has shorted. Needed 7/8" wrench.
Pentair Pool Heater Troubleshooting Guide - InTheSwim Pool Blog Pentair pool heater troubleshooting guide, Pentair Heater Error Codes [Reasons + Solutions], Water Flow Rates For Different Pentair Models, 2 More Confused Error Codes Of Pentair Heater. *17,16, 02, 08, 04, 06, 09, 0A Internal Errors: These errors can occur based on operating conditions and the UL 60730 required self-diagnostic safety software. Troubleshoot the high-pressure issue causing the error. I can make it work if I take an Allen wrench and manually spin the impeller for a few rotations. If necessary, clean the heat exchanger. Otherwise, there could be excess voltage sag caused by improper installation or improper supply voltage. Pentair IntelliFlo 2 VST. Does anyone know why it would cut off like this? It would self prime in about 1 minute and everything was happy. If the error has not cleared then proper troubleshooting will be required.
Also make sure both the skimmer Press the stop button the pump will stop. I will give it a try when I get home. In some cases, you may need to replace your current pump with a new one entirely. The ERR AFS Error Code 4. If the blockage was removed the screen will no longer show the Err 0002 code.
Product Warranty Information for Pool & Spa Equipment - Pentair When a problem is diagnosed as a consequence of this examination, you must address the problem. If the pump isnt running, press the start button to power it on. The Hole in One Basket: Connect a Cleaner at the Skimmer and Prevent Debris from Clogging the Pump! How long does a Pentair pool heater take to heat a pool? 1A Power Module over current detected: If this error displays multiple times, then there may be a problem with the pumps rotating assembly. Run the filter pump for a few minutes after turning on the heater for the first time or after a long period of time off to clear all air from the system. 21 -Communication link between HMI and motor control has been lost. brand new pentair vs gives out code EOFF ,then shuts off . Read our article on Pentair ignition failure to learn more. Speed 3 LED/button will select the third speed which is 2350 RPM.
New Pentair pump giving error codes 0002 and 000F : r/pools - reddit I have an error code on my Pentair variable speed pump. It Ran fine all summer. scheduled, flip open the top and see if there is an error code of some kind. choice for a Variable Speed Pump. I have a pentair superflo vst pump installed about 6 months ago has been working great but now has a code Err oooF checked power and no problem there has proper voltage I think it is the drive you can Riptide Vacuum System Steering Knuckle Upgrade! 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. Any new postings here are unlikely to be seen or responded to by other members.
How to Repair Pentair Master Temp Error E05 or E06 - YouTube The alphabetical list of hot tub error codes below covers all major manufacturers of spas and spa controls, including ACC, Balboa, Brett Aqualine, CTI, Dream Maker, EasyPak, Gecko, Hurricane, Hydro-Quip, Jacuzzi Whirlpool, Len Gordon, Maax, Master Spas, Pinnacle, Spa Builders Group, Spa Quip, Sundance, and Vita Spas, among others. Be sure to contact us through our website for our variety of services.. You must log in or register to reply here. We are a registered 501(c)3 non-profit that is funded by user donations. Generally just warranty it and the new one works fine. I have same code. Pentair Pool Pump Not Working? Gently turn it back in forth until the impeller begins to spin freely again.
Pentair Pool Heat Pumps Troubleshooting Guide It is probably a built-in Once the impeller spins freely the blockage has been cleared. failsafe so that the pump doesnt overheat and become damaged. I went and checked the pumped and the display screen said "Err 0021".
Pentair Minimax NT Heater Error Codes - INYOPools.com If Code ERR is shown on the LED display at any time, turn the heater off at the power switch and then turn the heater back on. Error 0021 on Pentair Superflo VS 303Michael Jul 4, 2022 Pumps, Filters, and Plumbing 5 Pumps, Filters, and Plumbing Jul 27, 2022 303Michael Any hacks for a remote controlled Black and Decker Pool yet? If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. connected to the pool, make sure you are using an in-line leaf canister. Save my name, email, and website in this browser for the next time I comment. It says "Err" and then "0002" and won't turn on. turn it off. At ePoolSupply and poolinfloor.com, we know our pool parts. . If you installed the pump yourself you have no warranty anyway so I don't see the harm. Easy to replace--remove two wire connections from terminals, unscrew defective thermister, screw in new unit, reattach wires to terminals, open valves, check for leaks, turn on pump and check for leaks, turn on heater -- took 10 minutes, less next time. Any new postings here are unlikely to be seen or responded to by other members.
How To Reset Pentair IntelliFlo Variable Speed Pump - The Pool Industry You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground. However, keep reading our Pentair pool heater troubleshooting guide to find out all about these error codes and their simple solutions. If purchased online will only receive a sixty-day limited warranty. Simply open the front door and look directly behind the control board. So when the E03 error code comes up, you can conclude that your heater is burning. This could be caused by normal voltage variation and will clear itself. screwdriver. Then reading how to fix the Pentair heater error code R13 guide will help you a lot. Please consider. its quick and easy way. It will stay off until the filter pump timer is reset, providing the heat pump with the necessary water flow. Also make sure both the skimmer and pump basket do not have rips or tears which could allow debris to get through and into the pump impeller. It may not display this or other websites correctly. I figured it out. It would self prime in about 1 minute and everything was happy. Who Makes the Best Pool Equipment -Pentair, Hayward, Jandy or Off Brands? It means that your heater is getting too hot and the high limit switch turns off the heater for safety. ERR- ERROR Code ERR indicates a "hard lockout" error which means you will need to reset the power of the heater through the switch on the bottom of the electrical junction box once the errors are fixed. Call the installer and have them check it out or have them get a warranty tech from Pentair to fix it. I happened to have a deep socket. to remove the pump lid and pump basket, then I spin the impeller with a
Inground Pool Pumps | Pentair When the temperature of the water going through the heat exchanger for the second time exceeds 140F, the Pentair pool heater error code AGS occurs. I installed a new Superflo VS pump on my 16x36 inground pool. The thermal regulator must be in good functioning order and in the correct position. Its like not insulating your houses loft if you dont utilize a sun cover. external slip) COPYRIGHT 2023. Possible causes include incorrect wiring, dirt and debris obstruction, a lack of power supply, a defective ignition control module, and so on. Check out the chart below to see which range is best for your model. Then turn it on and it works fine. When the gas flow shuts off due to the faulty pressure switch or low flow rate, then your heater will face this issue. Error Code ERR PS: Water Pressure Switch Is Open 7. It is probably a built-in failsafe so that the pump doesnt overheat and become damaged. What it means:refrigerant systems high-pressure switch is open, What it means:refrigerant systems low-pressure switch is open, What it means:5 faults have occurred within the heat pumps last cycle, Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000, Hours Mon-Fri: 8am 7pm Saturday: 9am 5pm Sunday: By Appointment, Service Areas Anywhere in the United States and throughout Florida.Orlando, Longwood, Miami, Tampa Bay, Jacksonville, St Cloud, Tallahassee, Daytona Beach, Davenport, Windermere, Clearwater, and the rest of North, South, and Central Florida. The ERR HLS code means that your heaters high-limit switch is stuck open. if you have problem to your pool pump pentair. Hopefully will warm up soon and I can reset. Impeller is stuck or jammed with debris. Pentair IntelliFlo3 VSF 3.0HP with I/O Board, Youtech - Home Services Digital Marketing Agency. Only active in Filter and Manual modes. If it Make sure that the pump is on by ensuring that the LED power is on. Check to make sure the wire supplying . I set up a gopro for hours and finally caught it giving and error 0021.Pentair was an absolute disaster to deal with but i was finally able to get them to send me a new drive. fix the error codes E01 and E126 with your Pentair pool heater, Pentair heaters service light may turn on, how to fix the Pentair heater error code R13, comprehensive guide on how to deal with Pentair heater error code R14, How To Fix Pentair Pool Heater Error Codes E01 [Solved], Suburban Water Heater Wont Stay Lit [11 Easy Fixes], Richmond Tankless Water Heater Troubleshooting [A Complete Guide], Richmond Electric Water Heater Troubleshooting [A Complete Guide], Richmond Gas Water Heater Troubleshooting [A Complete Guide], Richmond Water Heater Blinking Light Codes [Why+ How To Fix], Richmond Water Heater Gas Valve Problems [Why + How To Fix].
The Err 0002 can also indicate a wire is loose in the pump or a poor connection. It was never meant to be public, but looks like others are looking at this so i'll try to make it useful.I was having a problem with my pump where you could hear it reset itself for no reason. ERR PS Error Code Water Flow Rates For Different Pentair Models 2. Pool pump choice: Jandy 1.85HP VS Pump vs. Pentair Superflo VST 2.2, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. : https://youtu.be/huAt9BXLu9ISuperFlo VS Playlist: https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzPVisit my Website: http://www.swimmingpoollearning.com/eBook: https://www.swimmingpoollearning.com/swimming-pool-care-ebookYouTube Video Index: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.html A list of all of my videos.Follow Me:Google +: https://plus.google.com/+MrDgvb1/postsBlogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl Twitter: https://twitter.com/Mrdgvb1Join me on Patreon: https://www.patreon.com/poolguycoachingPodcast: http://www.buzzsprout.com/110832Podcast Website: https://www.thepoolguypodcastshow.com/Coaching Site: https://poolguycoaching.com/Shop INYOPools: www.inyopools.com?utm_source=youtube\u0026utm_medium=swimming-pool-tips Spin it Read our troubleshooting guide to figure out how to fix a faulty Pentair blower.
Sta Rite Pool Heater Error Codes [13 Easy Solutions] - FireplaceHubs Please disassemble the pump and investigate to see if there is a problem with the impeller or mechanical seal. If you get really fine particle debris, you can insert a filter sock or filter saver in the skimmer basket to trap the smaller particle debris that can fit through the pump basket and enter the impeller.
ERR IGN Error Code 5. Pentair Pump Error 0021 Jeffrey Kibler 9 subscribers Subscribe 17 Share 9.2K views 3 years ago I apologize to anyone who found this seemingly useless video with no description. The Err 0002 There are two ways to clear the blockage. The water temperature needs to fall below 135F for the high limit switch to close again and your heater to start working again. This was typically happening in quick clean mode. voltage and be used at 120V as well as at 230V. Hello , This is an inactive thread. Error Code ERR HLS: Hi Temperature Switch Is Open A malfunctioning thermistor, poor or damaged wiring, a bad control board, or a failed temperature sensor are all possible causes. 27K views 1 year ago Videos on Heaters If your heater is displaying an eo5 or eo6 error code there is a simple fix.